Mercedes tip liposuction cannula
Explore our advanced Mercedes tip liposuction cannula, manufactured for required results and efficiency in fat removal procedures. Featuring three opening Mercedes-shaped tips, this high-quality liposuction guarantees smoother fat extraction, minimal tissue trauma, and superior results for cosmetic and plastic surgeons. Its stainless steel tube offers durability, easy sterilization, and safety, making it an essential tool for body contouring and liposuction surgeries. Choose the Mercedes tip cannula for optimal performance, patient comfort, and outstanding clinical results in every liposuction procedure. We offer a complete selection of liposuction cannulas and fat transfer and fat grafting instruments. The Mercedes cannula is one of the key instruments for fat transfer to the breast, abdomen, thigh, etc. We assure you of a high-quality Mercedes cannula known as a three-port cannula in a circumferential pattern near the distal tip of the shaft. Moderate-weight Aluminum Handle and shaft made up of German steel, reusable along with Luer lock attachment, thread fitting short base attachment, and super Luer-lock options. Click the link to buy more liposuction cannulas & instruments.
Mercedes Tip Liposuction Cannula: Comprehensive Details.
| Family: | Liposuction—tubing |
| Tip Configuration: | Blunt, Round, Sizes 8G, 6G and 4G |
| Instruments Type: | Lipo Cannula |
| Disposable or Reusable: | Re-Usable and Autoclavable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485/9001. CE Mark |
| Sterility: | Non-Sterile |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.