- Stock: 5-6 Days
- Article #: Mam-001
We have Breast reduction surgery instruments set also joined with mastopexy, gynecomastia, and breast plastic-cosmetic surgery. Mastopexy is used to improve the appearance of a woman or uplift the saggy boobs of a woman, it also changes the shape and alters the texture of the breast of a woman while gynecomastia is the surgery in men for fat grafting/removal so that appearance could be improved and if any unwanted situation exiting in the body could also be removed.
We are the key manufacturer of breast reduction surgery instruments in the region being used in Breast reduction surgery, gynecomastia, and Mastopexy. We aim to provide breast reduction surgery instruments with high quality, very competitive prices, and on-time delivery.
The breast reduction surgery mammaplasty instruments set contains the following tools.
Scalpel Handle #7 | 2 | Atraumatic Breast Dissector 34cm. | 1 |
Scalpel Blade # 15(Box of 100) | 1 | Breast hook curved to left 36cm.. | 1 |
Jabeley scissors 13cm | 1 | Breast hook curved to right 36cm | 1 |
Metzenbaum scissors 8" Cvd | 1 | Freeman Areola Marker, 40mm. | 1 |
Adson Suture Forceps, 1 x 2 teeth w/tying platform | 2 | Freeman Areola Marker, 42mm… | 1 |
Gruenwald Bayonet forceps 19cm | 1 | Freeman Areola Marker, 45mm.. | 1 |
Baby Crile Wood needle holder 6" | 1 | Marx Breast Retractor 27cm… | 1 |
Baby Crile Wood needle holder 6" *T/C* | 1 | Breast Elevator 28cm.. | 1 |
Jabeley scissors 13cm Supercut. | 1 | Round Bowl for solution 60cc. | 1 |
Solz Gold Tip Scissors 8". | 1 | Mayo Heger Needle Holder 6"… | 1 |
Faurabeuf Retractor 12cm. | 1 | Total Units | 24 |
Lengenback Retractor 15x80mm. | 1 |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.