Cataract surgery instruments set—Ophthalmic Tools are designed for specific tasks during the procedure. Here’s a list of instruments used for cataract surgery and ophthalmic surgery.
1x Troutman Barraquer Colibri Type Corneal Utility Forceps 3″ 0.4mm
1x Castroviejo Blade Breaker And Holder 5 1/4″ Slide Catch
1x Castroviejo Needle Holder 5 1/2″ Tungsten Carbide with Lock Straight Serrated
1x Castroviejo Corneal Scissors 4 1/4″ Curved Right
1x Castroviejo Corneal Scissors 4-1/4″ Curved Left
1x Castroviejo Eye Speculum 3 3/4″ Medium 15X5mm O.D
4x Backhaus Towel Clamp 3 1/2″
4x Halstead Mosquito Micro Forceps Straight 5″
6x Halstead Mosquito Micro Forceps Curved 5″
1x Elsching O’brien Fixation Forceps 1×2 Angular Teeth With Catch 4″
1x Maumenee Eye Speculum Guard Over Locking Screw
1x Eye Dressing Forceps Serrated 4″ Straight Tips
1x Eye Dressing Forceps Serrated 4″ Half Curved Tips
1x Castroviejo Suture Forceps 4″ 1×2 0.5mm Teeth
1x Castroviejo Cyclodialysis Spatula 0.75mm Wide
1x Iris Forceps 4″ 1×2 Teeth Standard Straight Pattern
1x Iris Forceps 4″ 1×2 Teeth Standard Half Curved
1x Castroviejo Suture Forceps 4″ 1×2 0.9mm Teeth
1x Castroviejo Capsule Forceps 4″
1x Von Graefe Fixation Forceps 4 3/8″ Without Catch
1x Arruga Capsule Forceps 4″ Curved Standard
1x Eye Scissors Straight 4″
1x Eye Scissors Curved 4″
1x Desmarres Lid Retractor Size 3
1x Chalazion Mucocele Retractor 10×16 mm 9 cm
1x Stitch Scissors Curved 3 3/4″ Fine Tips – Blunt Blades
1x Stevens Tenotomy Scissors Straight 4 1/2″ – Blunt Tips
1x Westcott Tenotomy Scissors 4 1/2″ – Blunt Tips
1x De Wecker Iris Scissors 4 1/2″ Angled.
1x Eye Suture Scissors Curved Pointed Blades
1x Wilder Lens Loop Smooth
1x Kirby Double Hook And Expressor
1x Von Graefe Strabismus Hook Medium
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.