- Stock: In Stock
- Article #: Hnd-001
Hand surgery Surgical Instrument Set also linked
with sub-specialty of plastic and cosmetic surgery of hand. In hand surgery
multiple procedures being done for example finger broken being repairing, damaged
by burn etc. Hand surgery also known as chiroplasty, or cheiroplasty.
Our hand surgery instruments have 3years guarantee for their
intended use from the date of purchasing for its intended use only.
Specialty
about Hand surgery instrument set.
Material: German, Japaneses and
Stainless Steel, (depend on instrument functionality)
Finish= Satin (depend instrument
nature)
Packaging= Leather Kit(Hand carry).
Note= Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred.
1 | Halsted Mosquito Straight 5" | 6 | |
1 | Halsted Mosquito Curved 5 | 6 | |
1 | Adson Dress Ser 43/4 | 1 | |
Kocher Forceps Curved 1x2 5 1/2" | 1 | Adson Tiss 1x2 4 3/4 | 2 |
Kocher Forceps Straight 1x2 5 1/2" | 1 | Adson Brown Sd/grsp 43/4 | 1 |
2 | Allis Forceps 4x5 6 | 1 | |
1 | Allis Forceps 4x5 5 | 1 | |
1 | 1 | ||
1 | Joseph Hook 1/pr Sh 6 1/4" | 2 | |
1 | 2 | ||
Stevens Tenot Delicate Curved Bb 4 1/2 | 1 | Backhaus Towel Clamp 3 1/2" | 2 |
Metz Lahey Scissors Curved 4 1/2" | 1 | Backhaus Towel Clamp 5 1/4" | 6 |
Semkin Dress Forceps Delicate 5" Serr | 1 | Cushing Nerve/vein Retractor 9" | 1 |
Semkin Tiss Forceps Delicate 1x2 5" | 2 | 1 | |
1 | Frazier Suction Tube 8fr | 1 | |
Iris Scissors St Ss 4 1/2 | 1 | 1 | |
Iris Scissors Curved Ss 41/2 | 1 | Senn D/e Retractor Sharp 6" | 1 |
Mayo Diss Straight 51/2 | 1 | Ballengr Spong Forceps Straight Serrated 7" | 2 |
Mayo Diss Curved 51/2 | 1 | Ballnger Sponge Forceps Curved 7" Ser | 2 |
Metz Lahey Curved 5 3/4 | 1 | 2 | |
Hartman Mosquito Str 31/2 | 3 | Reynolds Scissors Nar Tip Curved 6 | 1 |
Hartmann Msq Curved31/2 | 3 | Crile D/e Retractor 4 1/2" | 1 |
Total Pieces………………………………………………………………………. | 72 |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
Refund / Return Goods Policy
- Item must be in unused condition and the original packaging Or unopened. Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.
- The customer is responsible for returning the item(s) to Gulmaher. Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).