Menu
Your Cart

Breast Reduction Surgical Instrument Set

Breast Reduction Surgical Instrument Set
Breast Reduction Surgical Instrument Set
Breast Reduction Surgical Instrument Set
Breast Reduction Surgical Instrument Set
Breast Reduction Surgical Instrument Set
$500.00
  • Stock: 10-12 Days
  • Article #: Bra-005

We have manufactured breast reduction surgery & surgical instruments and exporting worldwide since 2007. Our breast reduction surgery and surgical instruments are used in breast uplift, breast augmentation, mammoplasty, reconstruction of the breast, reshaping, and mastopexy. Breast reduction surgery & surgical instruments have a 3-year guarantee for their intended use from the date of purchase, during this tenure if any instrument fails to work return it and get repaired or a new one will depend on the instrument's nature. Make sure that Gulmaher Surgico is not liable to pay the courier charges. Courier charges would be payable from the buyer's end, and we will give just maintenance or repair free of cost for breast reduction surgery & surgical instruments.

                Specialty in breast reduction surgery & surgical instrument set.

  • Material: German, Japanese, and Stainless Steel, (depending on instrument functionality) 
  • Finish= Satin (depending on instrument nature)
  • Packaging:  Sterilizing Box.

Note= Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred. 


  • Breast reduction surgery & surgical set consisting of the following instruments.

Foerster Sponge Forceps Serrated 9-1/2"2Overholt Forceps Medium Jaw 8-1/4"2
Backhaus Towel Clamp  4-1/2"6Mayo-Hegar Needle Holder  7"2
Scalpel Handle #3  2Crile-Wood Needle Holder Narrow Jaws 6"2
Scalpel Handle #4  1Allis Tissue Forceps 4x5 Teeth 6"4
Mayo Dissecting Scissors Curved 6-3/4"1Lahey Traction Forceps  8"2
Metzenbaum Dissecting Scissors Curved 7"1Farabeuf Retractor Double End 6"1
Operating Scissors Straight Sharp/Blunt 5-1/2"1Tracheal Retractor Sharp Two Prong 6-1/2"2
Toennis Scissors Curved 7"1Volkman Retractor Four Prong Blunt 8-1/2"2
Gillies Forceps 1x2 Teeth Serrated 6"2Sims Retractor Large 3-1/2" x 1-1/2" Blade 2
Tissue Forceps 1x2 Teeth 7"2Weitlaner Self-Retaining Retractor Blunt 2x3 Teeth 4-1/2"2
Halsted Mosquito Forceps Curved 5"6Emesis Basin (Kidney Tray) 26 oz.  9-7/8" x 4-1/2" x 2-1/8"4
Crile Forceps Straight 6-1/4"2Iodine Cup 6 oz.  3-7/16" x 2"4
Baby Mixter fcps Curved Partial Serrations 7"4Total Pieces……………………………………..60


  • Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
  • Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.

Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*

  • Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
  • Aeration: As required to return to room temperature or to start the next cycle.
  • Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
  • Cleaning
 Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
1) DELIVERY TIMES CALE.

All orders received through the Gulmaher Surgico website are processed and, if the stock is available, despatched within 4 working days of receiving the order. Therefore, your ordered products will have to go through a production process, and the production period may vary according to the number of products and quantity, which may be 1-4 weeks.

2) LOST PACKAGE.

On rare occasions, we do experience losses whilst in transit. Please allow 10 days for the package to arrive from the date of despatch. If this time elapses and the goods do not arrive, please contact your nearest relevant courier office to check that no goods are being held. In the unlikely event that the package is not being held, please contact our Customer Services team who will be happy to assist in sending a replacement.

Please be aware that if we are not contacted within 3 weeks, an insurance claim cannot be made and thus you will be unable to claim any loss from Gulmaher Surgico.



3) TRACK AN ORDER.

For all your orders simply retrieve your tracking number from your account and then visit the relevant Courrier Website and track the order using their functionality.

Refund / Return Goods Policy

Any return must be assigned an RAN (Return Authorization Number) before it can be processed.  Please contact a Customer Service Representative for return authorization.  Returned merchandise will not be processed without an RAN#.

Customers have 30 days from the date of purchase to return an item for full credit.

  • Item must be in unused condition and the original packaging Or unopened.  Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.



  • The customer is responsible for returning the item(s) to Gulmaher.  Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).


Credit will be applied to the original method of payment for the order.

After 30 days the following restocking fees apply:

•After 30 days    25% restocking fee
•After 45 days    50% restocking fee

No returns are accepted after 60 days.

The following types of merchandise cannot be accepted for Refund/return:

A.Custom Made Instruments 
B.Special Orders / Discounted Invoice Products.
C.Discontinued Products 
D.Implants or Sterile Products Not in Original Unopened Package 
E.Merchandise Held Longer Than 60 Days


In the event of a defective product, the product must be reported to Gulmaher Surgico within 10 days of receipt of the goods or the claim will not be honored.

Please contact a Gulmaher Customer Service Representative with any questions.  Thank you.

Write a review

Please login or register to review
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Privacy Policy.