- Stock: 8-10 Days
- Article #: Abd-H001
We manufacture abdominal
hysterectomy surgical instruments specially used in operating wards/rooms or
private clinics. All surgical instruments regarding abdominal hysterectomy are German,
Japanese, and local stainless steel depending on the instrument's nature and
functionality. Gulmaher would like to explain about our hysterectomy surgical
instruments used in this procedure. A partial hysterectomy only removes the uterus
while a complete uterus and cervix are both removed and in the future, any woman cannot
be pregnant.
Specialty in abdominal
hysterectomy surgical
instruments.
Material:
German, Japanese, and Stainless Steel, (depending on instrument functionality)
Finish= Satin (depending on instrument nature)
Packaging Leather Kit(Hand carry).
Note: Due to instrument updates and pattern changes, equal substitutions may be necessary. Any changes to the set or your order will be communicated as they occur.
An abdominal Hysterectomy Surgical Instruments set contains the following tools.
Mayo Diss Sciss Str 6 ¾ | 2 |
Mayo Diss Sciss Cvd 5 1/2" | 1 |
Mayo Diss Sciss Cvd 6 3/4" | 2 |
Halsted Mosq Fcp Cvd 5" | 12 |
Kelly Fcp Str 5 1/2" | 6 |
Kelly Fcp Cvd 5 1/2" | 18 |
Roch-pean Fcp Cvd 6 1/4" | 18 |
Roch-pean Fcp Cvd 7 1/4" | 6 |
Roch-osch Fcps Str 1x2 6 1/4" | 12 |
Serrated Dressing Fcps 5 1/2" | 2 |
Serrated Dressing Fcps 8" | 1 |
Tissue Fcp 1x2 5 1/2" | 2 |
Tissue Fcp 1x2 8" | 1 |
Crile Murray Nh Serr 6" Tcsg | 2 |
Mayo Hegar Nh 7" Tcsg | 2 |
Mayo Hegar Nh 8" Tcsg | 2 |
Metz Lahey Del Crv Sciss 5 ¾ | 1 |
Sut Wire Cut Scis Ser Ang 43/4 | 1 |
Dir&tongue Tie (probe) 6" | 1 |
Ochsner Tr 20fr F 16fr Cath | 1 |
Poole Suct Tb Slip On Str 30fr | 1 |
Babcock Forceps 5.5" | 4 |
Babcock Forcep 8" | 4 |
Allis Tiss Fcp 3x4 6" | 12 |
Allis Tiss Fcp 5x6 7 1/2" | 4 |
Us Army Retr Set/2 D/e 8 1/4" | 1 |
Parker De Retr 5/8x5 Set/2 | 1 |
Kelly Retractor 9.5" 2"x2.5" | 2 |
Richardson W/sklrgrp Hndl Med | 2 |
Scalpel Handle number 4 | 1 |
Richardson-eastman Retr Set/2 | 1 |
Deaver Skl Grip Hdl #0 1" X10" | 1 |
Deaver Skl Grip Hdl #1 1" X12" | 1 |
Deaver Skl Grip Hdl #2 1"x 13" | 1 |
Deaver Skl Gr Hdl #3 1-1/2 X12 | 1 |
Deaver Skl Gr Hdl #4 2 X 12 | 1 |
Deaver Skl Gr Hdl #5 3 X 12 | 1 |
Zalkind Ribbon Retr 1 1/2x13" | 2 |
Volkman Retr Usa Shrp 6pr 81/2 | 2 |
Volkman Retr Usa Shrp 3pr 81/3 | 2 |
Balfour Abdom Retr Fenstr Bl7" | 1 |
Metzenbaum Scissors Cvd 7 | 1 |
Backhaus Towel Clamp 5 1/4" | 12 |
Foerster Sponge Serr Str 91/2" | 8 |
Deaver #5 3x12 | 2 |
Tissue Fcp 1x2 8" | 1 |
Allis Tiss Fcp 5x6 7 1/2" | 6 |
Tissue Fcp 1x2 12" | 1 |
Roch-pean Fcp Cvd 6 1/4" | 6 |
Roch Ochsner Fcp Str 1x2 7 ¼ | 6 |
Schroeder (braun) Ten Fcp 91/2 | 2 |
Schroeder Vulsllm Fcp Str 9.5" | 2 |
Heaney Single Tooth Hvy 8 1/4" | 4 |
Mayo Diss Sciss Cvd 9" | 1 |
Kelly-adson Sciss Cvd Sm 6 ¼ | 1 |
HYSTEREC CLMP ATRAU STR 9 1/2" | 1 |
HYSTEREC CLMP ATRAU SL CV 91/2 | 1 |
HYSTEREC CLMP ATRAU 3/4 CRV | 1 |
Scalpel Handle number 3 | 1 |
Total Units | 196 |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
Refund / Return Goods Policy
- Item must be in unused condition and the original packaging Or unopened. Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.
- The customer is responsible for returning the item(s) to Gulmaher. Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).