- Stock: 8-10 Days
- Article #: Skg-001
Dermatome instruments are used for skin grafting and skin grafting is a procedure through which skin is transplanted, or removed from the burn part of the body or trauma with the help of specially designed instruments. We offer dermatome instruments - skin grafting instruments in sets so that end-users can have a variety of skin grafting instruments for the surgery. Although this is a very small range of skin grafting instruments but very popular. Gulmaher Surgico guarantees the skin grafting instruments for three years from the date of purchase for their intended use only. During this period, we are liable to change free of cost all skin grafting instruments. The purchaser needs to pay for delivery charges.
Aspects of Dermatome Instruments - Skin grafting instruments.
- Material: German, Japanese, and Pakistani steel
depends upon the nature of the instrument.
- Finish:
Satin for common-use instruments also
customer demand would be preferred.
- Packaging: Plain polythene bags, Leather kits, and boxes depending on the instrument's nature with safety caps.
- Tungsten carbide: We make gold-plated half finish for tungsten carbide instruments like scissors, needle holders, etc.
Instruments Detail
Scalpel Handle #7 | 1 | Volkmann Bone Curette #2 | 1 |
Schink Dermatome Complete | 1 | Volkmann Bone Curette #3 | 1 |
Operating Scissor Curved, Sharp/Blunt, 5" | 1 | Volkmann Bone Curette #4 | 1 |
TC Halsey Needle Holders Serrated, 5 1/4" | 2 | Volkmann Bone Curette #5 | 1 |
Metzenbaum Scissor Curved, Delicate, 5 3/4" | 1 | Volkmann Bone Curette #6 | 1 |
Volkmann Bone Curette #4-0 | 1 | Iris Scissor Curved, Sharp/Sharp, 4 1/2" | 1 |
Volkmann Bone Curette #3-0 | 1 | Adson Tissue Forcep 1x2 Teeth, 4 3/4" | 2 |
Volkmann Bone Curette #2-0 | 1 | Adson Dressing Forceps Serrated, 4 3/4" | 2 |
Volkmann Bone Curette #0 | 1 | Strabismus Scissor Curved, Blunt/Blunt, 4 1/2" | 1 |
Volkmann Bone Curette #1 | 1 | Micro-Mosquito Forceps 1x2 Teeth, Straight, 4 3/4" | 6 |
ToTal …………………………………….. | 28 pieces | ||
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
Refund / Return Goods Policy
- Item must be in unused condition and the original packaging Or unopened. Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.
- The customer is responsible for returning the item(s) to Gulmaher. Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).