- Stock: In Stock
- Article #: AVF-001
We are manufacturing an AV (arteriovenous)fistula
surgical instrument set for connecting arteries with veins. AV (arteriovenous)fistula
surgical instrument sets are made up of German, Japanese, and local steel depending
on the instrument's nature and functionality. AV fistula surgical instruments play a very important role in making a functionally perfect blood-carrying mechanism.
Specialty
in AV(arteriovenous) Fistula Surgical Instrument Set.
Material: German, Japanese, and
Stainless Steel, (depending on instrument functionality)
Finish= Satin (depending on the instrument's
nature)
Packaging Leather Kit(Hand carry).
Note= Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred.
Scalpel Handle #7 | 1 | Lorna-Edna Towel Clamp 5 1/4" | 2 |
Mayo Dis Sciss Str 63/4 Tc | 1 | Frazier Suct Tube 8fr | 1 |
Metz Lahey Crv Std 5 3/4tc | 1 | Adson Tissue Fcp 1x2 4 3/4" | 2 |
Micro Mosquito Crvd 5" | 4 | Adson Dressing Fcp Serr 4 3/4 | 2 |
Halsted Mosq Fcp Str 5" | 4 | Potts-smith Dress Fcp Ser 7 Tc | 1 |
Halsted Mosq Fcp Cvd 5" | 6 | Potts-smith Scis 45 Ang 7 1/4" | 1 |
Roch-osch Fcps Str 1x2 6 1/4" | 2 | Debakey Atra Fcp Str 6 1/4 2mm | 2 |
Crile Fcp Cvd 5 1/2" | 1 | Ring Hndl Bulldg Deb At Cvd 5" | 2 |
Halsey Nh Serr Tc 5 1/4" | 1 | Ring Hndl Bulldg Debakey 5" | 2 |
Crile Wood Nh Serr Nar/jw 6"tc | 2 | Vascular Dilator Short Set Of9 | 1 |
Castro Nh W/lk Str Sm 5 1/2"tc | 2 | Us Army Retr Set/2 D/e 8 1/4" | 1 |
Debakey Cardiovascular Nh 7"tc | 1 | Richardson W/sklrgrp Hndl Smll | 2 |
Mixter Del Rt Ang Fcp 5 1/2" | 2 | Senn D/e Retractor Blunt6 1/4" | 2 |
Weitlaner Retr Bl 2x3 4 1/2" | 1 | Stev Tenot Sciss Crv 4 1/2"bb | 1 |
Alm Self-ret Ret 4x4 Bl 2 3/4" | 1 | WESCOTT TENOT SCISS BL 4 1/4 | 1 |
Allis Tiss Fcp 4x5 6" | 2 | Desmarres Lid Retr 14mm | 1 |
Roch Pean Fcp Cvd 9" | 1 | Zanger-Debakey Heparin Needle | 1 |
Gillies Skin Hook 7" 4mm | 2 | Bozeman Fcp S-crv 10 1/4" | 1 |
Blair-roll Ret Del 4pr Bl 51/2 | 2 | Diethrich Bulldg Clmps Ang 8mm | 4 |
Total Pieces………67 |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
Refund / Return Goods Policy
- Item must be in unused condition and the original packaging Or unopened. Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.
- The customer is responsible for returning the item(s) to Gulmaher. Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).