- Stock: 8-10 Days
- Article #: Amp-001
We are manufacturing amputation surgical
instruments set for removing limbs causing pain in body parts or
unwanted situations. Amputation surgical instruments are made up of German, Japanese, and local steel depending on the instrument's nature and functionality. Amputation
surgical instruments play a very important role to remove injured or deformed parts
of the body crippling may occur. Amputation surgical instruments are also linked with bone surgery.
Specialty in amputation surgical instruments.
Material: German, Japanese, and Stainless Steel, (depending on
instrument functionality)
Finish= Satin (depending on instrument nature)
Note: Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred.
Multi-Cut Utility Scissors Serrated Black 7-1/2" | 1 | Bruns Bone Curette Oval #0 6-3/4" | 1 |
Supercut™ Mayo Dissecting Scissors Straight 6-3/4" | 1 | Bruns Bone Curette Oval #3 6-3/4" | 1 |
Supercut™ Mayo Dissecting Scissors Curved 6-3/4" | 1 | Key Elevator 1" 7-1/2" | 1 |
Crile Forceps Curved 5-1/2" | 1 | Langenbeck Elevator Single End Narrow 7-1/2" | 1 |
Rochester-Ochsner Forceps Straight 1x2 Teeth 6-1/4" | 1 | Langenbeck Elevator Single End Wide 7-1/2" | 1 |
Scalpel Handle #4 | 1 | Wire Loop Handle For Gigli Saw Pack of 2 | 1 |
TC Mayo-Hegar Needle Holder Serrated Tungsten Carbide 6" | 1 | Putti Bone Raspatory Curved Ends Round and Half-Round Tapered 12" | 1 |
Tissue Forceps 1x2 Teeth 6" | 1 | Satterlee Bone Saw 12" | 1 |
Liston Amputating Knife 8" Blade 13" | 1 | Percy Amputation Retractor | 1 |
Stille-Luer Rongeur Double Action Straight 8-1/2" | 1 | Steel Ruler 12" | 1 |
Stille-Liston Rongeur Curved Double Action 10-1/2" | 1 | Sterilizing Tray 20" x 10-1/2" x 3-1/2" | 1 |
Total Units……. 23 | Weinstein Sterilizing Rack 5-1/2" | 1 | |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.
Refund / Return Goods Policy
- Item must be in unused condition and the original packaging Or unopened. Sterilized, taped, modified, or abused items cannot be returned or refunded for credit.
- The customer is responsible for returning the item(s) to Gulmaher. Gumaher will issue merchandise return labels if the return is a result of Gulmaher's mishandling (shipping error, etc.).