Auvard Weighted Vaginal Speculum is a single end vaginal speculum normally used in OB/GYN systems, for instance, vaginal hysterectomy or dilation and curettage. It is open with various front lines styles and three weight choices in order to oblige the necessities of the patient and the framework. The weight holds the speculum set up and gives an open view to the expert to perform the procedure. Auvard Vaginal Speculum is planned to keep the vagina canal open and free the gynecologist's hands for various sort of perceptions. It incorporates a half-tube bowed at a right edge with a round weight on the handle. The instrument is open in various loads and front line sizes to oblige a wide extent of cases. It is accessible with Fix weight as well as in remove able weight.
Additional Information about Auvard Weighted Vaginal Speculum.
Surname: Auvard
Tip Configuration Blunt
Instrument Type Vaginal Specula.
Material: Stainless Steel High-grade
Disposable or Reusable: Reusable
Sterile or Non-Sterile Non-Sterile
Latex or Latex-Free Latex-Free
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.