- Stock: In Stock
- Ref #: 100-034
Available Options
Carraway Fat Harvester Cannula — Spiral Three-Port Diagonal Hole Design
The Carraway Fat Harvester Cannula from Gulmaher Surgico features a distinctive spiral three-port (diagonal holes) configuration—purpose-engineered for efficient, atraumatic fat harvesting during liposuction and fat transfer procedures.
Also known as the Carraway spiral three-port harvester cannula, this instrument is a trusted choice for plastic surgeons doing body contouring, facial fat grafting, Brazilian Butt Lift (BBL), and reconstructive fat transfer surgeries.
What Makes the Diagonal Hole Design Unique
The three diagonal (spiral) ports are set at exact angles along the cannula shaft, so we can harvest adipose tissue from multiple planes at the same time with one insertion. This design maximizes fat collection efficiency, reduces procedure time, and preserves fat cell viability — a critical factor for successful fat grafting outcomes.
Key Features: Carraway spiral three-port harvester cannula
- 3 diagonally positioned spiral ports for multi-directional fat extraction
- Surgical-grade stainless steel — autoclavable and fully reusable
- Smooth, polished shaft for minimal tissue trauma
- Compatible with luer lock and Toomey syringes
- Available in multiple gauges and lengths to suit varying anatomical needs
- A lightweight, ergonomic handle reduces surgeon fatigue in long procedures
- Individually packed in sterile plain plastic tube with cap
Wholesale & Export:
Manufactured in Sialkot, Pakistan, Gulmaher Surgico supplies Carraway harvester cannulas to plastic surgery clinics, hospitals, and distributors across the USA, UK, Europe, and worldwide at competitive wholesale pricing. Precision harvesting tools are designed to achieve superior surgical results.
| Family: | Liposuction—tubing |
| Tip Configuration: | Round, sizes 2 mm to 5.0mm |
| Instruments Type: | Lipo Cannula |
| Disposable or reusable: | Re-Usable and Autoclavable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485/9001. CE Mark |
| Sterility: | Non-Sterile |
| Hub: | Fixed handle, Luer-Lock, Super Luer-Lock, and Threaded (Nouvag) Fitting |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.