Craniotomy Surgical Instrument Set
$550.00
- Stock: 8-10 Days
- Article #: Cra-002
Craniotomy surgical instruments have a very tentative range of instruments to diagnose the problem inside the skull or brain. Our Craniotomy surgical instruments are specially designed by looking need of instruments regarding this surgery. We have a 3-year guarantee for their intended use from the date of purchase.
The specialty about Craniotomy surgical instrument set.
- Material: German, Japanese, and Stainless Steel, (depending on instrument functionality)
- Finish= Satin (depending on the instrument's nature)
- Packaging Leather Kit(Hand carry).
Note= Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred.
Detail of Instruments
- Jansen Retractor Blunt 3x3 Blades 4" 2
- Weitlaner Retractor Blunt 3x4 Teeth 6-1/2" 2
- Scalpel Handle #3 1
- Scalpel Handle #4 1
- Scalpel Handle #7 1
- Solid Bar Handle For Gigli Saw Pack of 2 2
- Adson (Ewald) Dressing Forceps Serrated 4-3/4" 2
- Adson Tissue Forceps 1x2 Teeth 4-3/4" 2
- Backhaus Towel Clamp 5-1/4" 6
- Cushing Brain Forceps Delicate Serrated 7" 2
- Cushing Brain Forceps Delicate 1x2 Teeth 7" 2
- Ruskin Rongeur Straight 7-1/4" 2
- Foerster Sponge Forceps Serrated 9-1/2" 4
- Halsted Mosquito Forceps Straight 5" 6
- Halsted Mosquito Forceps Curved 5" 6
- Luer Bone Rongeur Curved 8mm x 10mm Bite 7" 1
- Stille-Liston Bone Forceps Curved Double Action 10-1/2" 1
- Mayo-Hegar Nh Serrated 7" 2
- Gigli Saw Wire 12" 1
- Gigli Saw Wire 20" 1
- Operating Scissors Straight Sharp/Blunt 6" 1
- Mayo-Stille Dissecting Scissors Straight 6-3/4" 1
- Mayo-Stille Dissecting Scissors Curved 6-3/4"; 1
- Metzenbaum Dissecting Scissors Curved 7" 1
- Taylor Dural Scissors w/ Probe Tip 5-1/2" 1
- Cover for Instrument Tray 1
Total Pieces……………………………………. 53
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.