We are a key manufacturer of Chalazion surgery & surgical instruments and exporting worldwide since 2007. Our Chalazion surgery and
surgical instruments being used in eyelid surgery or blepharoplasty. Chalazion surgery
& surgical instruments have a 3-year guarantee for their intended use from the
date of purchase, during this tenure if any instrument fails to work return it
and get repaired or a new one will depend on the instrument's nature. Make sure that
Gulmaher Surgico is not liable to pay the courier charges. Courier charges
would be paid from the buyer's end and we will give just maintenance or repair free of
cost for Chalazion surgery & surgical instruments.
Specialty
in Chlazion surgery & surgical instrument set.
Material: German, Japanese, and
Stainless Steel, (depending on instrument functionality)
Finish= Satin (depending on instrument
nature)
Packaging: Sterililizing
Note: Due to instrument updates and pattern changes equal substitutions may be necessary. Any changes to the set or your order will be communicated as occurred.
Iris Scissors Straight Sharp/Sharp 4-1/2" | 1 | Lester Conjunctival Forceps Non-Magnetic 1x2 Teeth 4" | 2 |
Stevens Tenotomy Scissors Straight Blunt/Blunt 4-1/2" | 1 | Bonaccolto Utility Forceps Cross Serrated at Tips 1.2mm Jaw | 1 |
Castroviejo-Kalt Needle Holder 5-1/2" | 1 | Halsted Mosquito Forceps Straight 5" | 2 |
Meyhoefer Chalazion Curette #1 | 1 | Desmarres Chalazion Forceps Large 3-1/2" | 1 |
Meyhoefer Chalazion Curette #2 | 1 | Jaeger Lid Plate Stainless Steel 3-1/2" | 1 |
Graefe Fixation Forceps Without Catch 4-1/8" | 1 | Desmarres Lid Retractor 16mm | 1 |
Graefe Fixation Forceps With Catch 4-1/8" | 1 | Self-Retaining Retractor Delicate Sharp 3x3 Prongs 1-1/2" | 1 |
Total Pieces……………………………………….. | 16 |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.