Cobra Bibevel —Two Ports Liposuction Cannula
Enhance liposuction with the Cobra Bibevel liposuction cannula and compatible accessories. Discover efficient, precise fat removal with advanced surgical tools. The cobra bibevel cannula for liposuction is crafted for precision fat removal, offering a unique bibevel tip that ensures smooth, controlled aspiration and minimal tissue trauma. Its ergonomic handle provides superior control, while the high-grade stainless steel material guarantees durability and effortless sterilization. A luer-lock hub makes a secure, leak-proof connection with standard cannulas, which helps keep the instrument stable. The Super Luer-lock hub gives more stability and control than the standard luer-lock attachment. Moreover, the fixed handle assists in the power-assisted liposuction procedure, and the thread fitting base also works fine with the power-assisted liposuction machine (Novaug).
Aspiration Tubing: Flexible, kink-resistant, medical-grade material; allows for uninterrupted fat removal; available in multiple lengths.
Compatible with mechanical systems to enhance cannula movement; reduces surgeon fatigue and optimizes fat extraction.
Manufactured from AISI 316 medical-grade stainless steel with a corrosion-resistant mirror finish. The smooth, polished surface ensures atraumatic insertion and reduces friction during the cannula pass.
Cobra Bibevel Two-Port Liposuction Cannula: Comprehensive Details.
| Family: | Liposuction—tubing |
| Tip Configuration: | Blunt, Round, Sizes 12G to 4G (2mm to 5mm) |
| Instruments Type: | Lipo Cannula |
| Disposable or reusable: | Re-Usable and Autoclavable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485/9001. CE Mark |
| Sterility: | Non-Sterile |
| Hub Attachments | Luer-Lock, Fixed Handle, Super Luer-Lock & Threaded Fitting |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.