Coleman Tumescent Infiltration Cannula
The Coleman tumescent infiltration cannulas are specialized plastic and cosmetic surgery instruments designed to facilitate the infiltration of tumescent fluid during fat grafting procedures. Available in a comprehensive range of sizes from 12G to 4G in millimeter from 2.0mm to 5.0mm (select the required options) these cannulas used for both small- and large-volume procedures, making them highly valued tools for surgeons performing fat transfer and liposuction procedures.
Manufactured to precise medical standards, Coleman tumescent infiltration cannulas are crafted from high-quality stainless steel, ensuring durability, resistance to corrosion, and ease of sterilization. The selection of sizes and multiple hole options allows practitioners to select the most appropriate cannula for the area being treated: smaller gauges (such as 12G) are ideal for delicate, targeted fat grafting in areas like the face, neck and chin, where precision is essential, while larger gauges (up to 4G) are well-suited and being used in bulk for infiltrating larger volumes of tumescent fluid in body areas such as the abdomen, thighs, breast or buttocks.
Key Features about the Coleman tumescent infiltration cannula:
| Family: | Liposuction — tubing |
| Tip Configuration: | Blunt, Round, Sizes 12G to 4G |
| Instruments Type: | Lipo Cannula |
| Disposable or Re-Usable: | Re-Usable and Autoclavable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485-9001. CE Mark |
| Sterility: | Non-Sterile |
| Hole Configuration & Sizes | 18 to 30 Holes & 15cm to 30cm in working length |
These cannulas feature a smooth, polished surface and rounded, atraumatic tips to minimize tissue trauma and discomfort during insertion and fluid infiltration. The ergonomic design also includes a luer lock hub, Fixed handle for large volume procedure, threaded fitting covering Nouvag brand, and toomey connection, ensuring a secure attachment to syringes or infusion tubing for efficient fluid delivery. The internal diameter and length of each cannula are optimized to enable consistent, even distribution of tumescent solution, which is critical for effective fat harvesting and graft survival. Our Coleman tumescent infiltration cannulas are essential surgical instruments for safe and effective fat grafting procedures. Click for more verity of Liposuction cannula and Instruments.
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.