- Stock: In Stock
- Ref #: 100-015
Available Options
Blunt Tip Dermal Filling Cannulas — Precision Instruments for Aesthetic Practitioners
Gulmaher Surgico's blunt tip dermal filling cannulas are engineered for plastic surgeons, dermatologists, and aesthetic injectors who demand safety, control, and superior patient outcomes. Unlike traditional sharp-tip needles, our blunt-tip microcannulas glide through subcutaneous tissue without cutting through blood vessels or nerves—significantly reducing the risk of bruising, swelling, and vascular injury. This makes them the preferred choice for modern dermal filler injection procedures, including lip augmentation, cheek contouring, jawline definition, nasolabial folds, and under-eye (tear trough) treatments.
Key Features: Blunt-Tip Dermal Filling Cannulas
- Available Gauges: 20G to 12G
- Available Lengths: 5 cm, 10.5 cm, and 15cm
- Blunt rounded tip for atraumatic tissue navigation
- Flexible, kink-resistant stainless steel tubing for precise depth control
- Hub depth markings for accurate injection monitoring
- Compatible with luer lock and luer slip syringes
- Non-Sterile, re-usable, individually packed
- Manufactured to CE and ISO 13485 standards
Wholesale & Export:
Manufactured in Sialkot, Pakistan — the global hub for surgical instruments — Gulmaher Surgico offers competitive wholesale pricing, bulk order discounts, and reliable exports to the USA, UK, Europe, and worldwide. Upgrade your practice with instruments built for precision, safety, and results. See the complete collection of the liposuction cannulas.
| Family: | Liposuction—tubing |
| Tip Configuration: | Round, sizes 1 mm, 1.5 mm, and 2.0mm |
| Instruments Type: | Lipo Cannula |
| Disposable or reusable: | Re-Usable and Autoclavable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485/9001. CE Mark |
| Sterility: | Non-Sterile |
| Hub: | Luer-Lock & Super Luer-Lock |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.