- Stock: In Stock
- Ref #: Fac-001A
Facial Liposuction Cannula Set: Instruments for face contouring.
Facial liposuction requires extreme precision, making the choice of surgical instruments critical. A facial liposuction cannula is a specialized micro stainless steel pipe with a starting diameter from 0.8 mm (20 gauge) to 2.4 mm (10 gauge) with various lengths and tip shapes, an ultra-fine cylindrical cannula designed specifically for targeted fat removal and sculpting in the face, neck, and submental (double chin) region.
Facial liposuction cannula, micro lipofiller, set for face, neck, and chin lipoplasty surgery, consisting of:
|
| ||
|
|
Like other standard body cannulas, facial liposuction cannulas are treated with micro-cannulas.
Key Features:
Material: Stainless steel, highly mirror finish, assists in smooth insertion into the required area.
Cleaning: Autoclavable; sterilization can be done after each procedure.
Optimized Tip Designs: Tumescent Infiltrator, Sorensen Harvester, and Microinjector.
Accessories: include syringe locks for 10 cc and 20 cc syringes. Syringe-Holding Stand and Transfer Luer-to-Luer.
Versatile Hubs: Equipped with standard Luer Lock hubs to attach seamlessly to syringes for manual aspiration.
Clinical Applications: Submental and neck fat reduction, jowl contouring, and jawline definition Cheek refinement: Micro-fat harvesting for facial fat grafting.
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.