Trepsat Facial Flap Dissecting Scissors
The TrepSat Facial Flap Dissecting Scissors are precision surgical instruments specifically designed for facial surgery. Hand-crafted from high-quality stainless steel material, they offer exceptional durability and are rust-free and prepared with sharp cutting edges for consistent performance in the operating room. The Trepsat scissors have a slim pattern and slightly curved shanks, allowing surgeons to perform dissection and separation of facial tissue with minimal trauma, thereby enhancing surgery and patient value.
The ergonomic finger rings and balanced handle design provide optimal control and comfort, reducing hand fatigue during prolonged use. This makes them especially suitable for reconstructive and cosmetic facial surgeries, such as rhytidectomy (facelift), flap elevation, and skin graft procedures, where precision and gentle handling of tissues are very important.
Key Features about the Trepsat Facial Flap Dissector and Scissors Set:
| Family: | Dissecting Scissors |
| Tip Configuration: | Blunt, Round |
| Instruments Type: | Scissor / Elevator |
| Disposable or Re-Usable: | Re-Usable and Autoclaveable |
| Material: | Stainless Steel high-grade |
| Certification: | ISO 13485-9001. CE Mark |
| Sterility: | Non-Sterile |
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.