- Stock: In Stock
- Article #: 2927-10
Available Options
Weitlaner Retractor is a self-retaining finger-ring retractor with a cam ratchet lock used for holding back tissue and exposing a surgical site. It has curved shanks that lead to blades with between two and six sharp or blunt, outward-curving prongs. The prongs interdigitate when the instrument is closed. We have a large collection of weitlaner self-retaining retractors with multiple sizes in the slot.
- Purpose:
Exposure: The Weitlaner retractor is designed to keep incisions open and expose underlying structures, making it particularly useful in surgeries involving the abdomen, thorax, and other areas where deep access is required.
- Stability: It allows the surgeon to maintain a stable field of view without the need for continuous manual support, enhancing precision during the procedure.
Types:
- Self-Retaining: The Weitlaner retractor is typically a self-retaining type, meaning it has a mechanism that holds it in place once positioned, freeing up the surgeon's hands for other tasks.
Considerations:
- Tissue Protection: To minimize trauma and discomfort, care should be taken to avoid excessive pressure on surrounding tissues.
- Size and Configuration: Weitlaner retractors come in various sizes and configurations to accommodate different surgical needs and patient anatomies.
- Sterilization: As with all surgical instruments, proper sterilization before and after use is essential to prevent infection.
If you have any specific questions about the Weitlaner retractor or its applications, feel free to ask!
- Sterilization: Surgical instruments may be steam autoclaved at a temperature of 121°C (250°F) for 30 minutes or flash autoclaved at a temperature of 127° to 132°C (260° to 270°F) for 10 minutes.
- Recommended Sterilization Parameters: PRE-VAC Unwrapped Goods Cycle 5 minutes at 132° C/270° F. Dry Time: none recommended.
Wrapped Goods Cycle 5 minutes @ 132° C/270° F Dry Time: 5‐20 minutes*
- Recommended Gravity. Unwrapped Goods Cycle 10 minutes @ 132° C/270° F Dry time: none recommended. Wrapped Goods Cycle 30 Minutes @ 132° C/270° F Dry Time: per facility recommendation. Wrapped Goods Cycle 60 Minutes @ 132° C/270° F Dry Time: per facility recommendation. *Depending on Hospital Protocol* Warning: Flash sterilization is not the recommended sterilization method. All surgical instruments and parts should be steam autoclaved when time permits. However, flash sterilization may be used when there is an immediate need for an instrument, injector, or accessory and there is no other alternative.
- Aeration: As required to return to room temperature or to start the next cycle.
- Contraindication: Hospital policy and procedure(s) take precedence over this protocol. Failure to use approved cleaning and sterilization procedures may void the warranty.
- Cleaning Instructions: Cleaning: All instruments must be cleaned to remove contaminated substances before sterilization. After each use, perform an initial cleaning within the sterile field by wiping the tool or instrument free of blood and body fluids. Then clean the instrument thoroughly with a mild soapy solution. Do not use alkaline-based cleaners. Complete preparation for sterilization by hospital procedure using an approved cleaning agent. Do not run any type of abrasive materials or steel brushes through the lumen of the tool. The abrasive material can score the inside of the tool, rendering them inefficient. After flushing, the instrument needs to be well-rinsed with warm to hot water. Visually inspect each instrument to ensure all fatty deposits are removed. All instruments should be cleaned and rinsed with mild, non-abrasive, grease-removing cleaners before they are sterilized. Gulmaher Instruments recommends that during the cleaning and rinsing procedures, all instruments should be inspected. Ultrasonic cleaning after manual cleaning is recommended.